42U Cabinet: Bayable Sides
Brush-Strip Entry, Split Rear Doors and 1,300 kg Design Static Load
Floor-standing server racks, network and colocation cabinets, open-frame relay racks, wall-mount and outdoor cabinets, and the accessories that fill them. Built to the 19-inch standard in sheet and tube steel, powder coated, in the size and door layout you specify.

From a single wall cabinet to a row of data-hall cabinets with containment, we make the metalwork to your specification.

Floor-standing server and network cabinets

Open-frame, two-post and relay racks

Wall-mount cabinets and edge racks

Outdoor, pole-mount and telecom cabinets

Cable managers, PDU rails, shelves and doors

Aisle containment, raised floors and cooling frames
The racks customers ask for most. Add them to your enquiry list and we quote them together.
Brush-Strip Entry, Split Rear Doors and 1,300 kg Design Static Load
48U 800 × 1,200, 1,800 kg Design Static Load, Liquid-Cooling Ready
42U 800 × 1,100 with Individually Keyed Split Front and Rear Doors
45U, Floor-Anchored with Cable Runway and Top Brace (Exchange Grade)
The open-frame version of the server rack: four 2 mm posts, top and bottom frames, and four EIA-310 rails on slotted brackets so the mounting depth can be set from about 500 to 750 mm.
These are the options customers specify most. The final configuration is confirmed on your drawing and in your quotation.
| Height | 22U, 24U, 42U, 45U, 47U or 48U (1U = 44.45 mm) |
|---|---|
| Width | 600 mm or 800 mm |
| Depth | 800 to 1,200 mm, to suit your deepest equipment |
| Doors | Perforated, glass or solid; single or split front and rear; individually keyed leaves |
| Material | CRCA or galvanised sheet and tube; stainless steel on request |
| Finish | Polyester powder coat in the RAL colour you choose |
| Cable entry | Brush-strip entries in the roof and floor, cable managers, wall feed-through panels |
| Cooling provision | Perforated doors, fan-tray cut-outs, door-mounted cooler and heat-exchanger cut-outs |
| Mounting | Castors, levelling feet, floor-anchor plates, anti-tip stabilisers, baying kits |
| Fittings | Shelves, PDU rails, blanking panels, cable managers, earth bonding |
Rack units, rail spacing and hole patterns follow the 19-inch convention, so servers, switches, patch panels, PDUs and shelves from other makers fit. Tell us the equipment depth and weight and we set the post, rail and base thickness to suit.

U is the rack unit: 1U is 44.45 mm (1.75 inch) of mounting height. A 42U rack has 42U of space for equipment. The '19-inch' in 19-inch rack is the width of the equipment panel (482.6 mm); the opening between the rails is about 450 mm.
Yes. Heights, widths, depths, doors, finishes and fittings are specified per order. Send a drawing or describe your equipment and we quote.
Yes: 42U network and server cabinets, colocation cabinets with keyed split doors, 47U network core racks, 48U GPU racks and the containment and floor parts around them.
CRCA or galvanised sheet and tube steel with a polyester powder coat is standard. Stainless steel is available for corrosive or clean environments.
Use the quote form or call. Tell us the height, width, depth, quantity, door type, finish and delivery place. We reply with a quotation and, for a new design, a drawing for your approval.
Tell us your destination and we include delivery in the quotation. Export enquiries are welcome.
Tell us what you need, how many, and by when. We reply with a clear quotation.