19" Server Racks
Standard rack enclosures for IT equipment mounting. Made to order in CRCA 2.0 posts, 1.2 panels, to your drawing.
Floor-standing server and network cabinets, colocation and GPU-server racks, open-frame relay racks, outdoor telecom cabinets, cable trays and the brackets and shelves that fill them, made to your size and finish in Chennai.

Data centres, exchanges and telecom sites are built from the same sheet-metal parts: 19-inch racks and cabinets, wall-mount edge cabinets, outdoor battery and equipment cabinets, cable ladders and trays, and the shelves, rails and brackets inside. We make all of these, in the width, depth, height and door type you specify.
Our rack range starts at a general-purpose 42U cabinet and extends to colocation cabinets with a separate lock on each door leaf, a 47U network core rack with integral cable managers, a seismic-ready rack with floor anchoring, and a 48U rack for GPU servers with provision for liquid cooling. See the full server rack and network cabinet range.
For sites outside the building we make double-wall, sun-shielded outdoor cabinets with heat-exchanger cut-outs, fibre distribution hub pedestals, shelter-to-tower cable bridges and antenna pole clamp sets. Inside the hall: overhead cable ladders, top-of-rack trays, raised-floor pedestal kits and rear-door heat-exchanger frames.
Every product is made to order, in the size, material and finish you specify.
Add any product to your enquiry list and we quote them together. Anything not listed is made to your drawing.
18 products
Standard rack enclosures for IT equipment mounting. Made to order in CRCA 2.0 posts, 1.2 panels, to your drawing.
A premium server cabinet 600 wide × 1,200 deep: the extra depth takes long servers and the cable space behind them.
A 24U network cabinet 600 × 600 for switches and patch panels: lighter 1.5 mm posts, a glass or perforated front door and a fixed rear door.
A high-density rack with 2.5 mm posts, 80 % open doors and sealing strips so it works in hot/cold aisle containment.
A 32U enterprise floor cabinet with lockable doors and side panels and cooling-ready roof cut-outs (height between the 24U and 48U ends of the range).
Brush-Strip Entry, Split Rear Doors and 1,300 kg Design Static Load
More in this group: Network Core Rack · Seismic-Ready Server Rack · Colocation Cabinet · Half-Height Edge Rack · Battery Cabinet for Rack UPS · Relay Racks · Two-Post Telco Relay Rack · 4-Post Open-Frame Rack (Adjustable-Depth Rails) · Modular Expansion Frames · Open Rack
12 products
Space-saving wall cabinet whose 19-inch rails swing out on hinges for rear access. Made to order in CRCA 1.2-1.5 mm, to your drawing.
A wall fibre-management unit for 12-96 fibres: splice trays, patch adaptors and slack storage behind a lockable door, with bend-radius guides folded from the same sheet.
PCI expansion chassis for network hardware. Made to order in CRCA 1.2-1.5 mm, to your drawing.
A sealed glass-door wall cabinet runs hot with switches inside. A perforated lockable door plus a thermostat-controlled fan tray is the practical upgrade.
More in this group: Small-Cell / 5G Radio Enclosure · 12U Outdoor Wall / Pole Cabinet · Power Distribution Units · 1U Fibre Patch Drawer (LIU)
7 products
A field cabinet for batteries and telecom equipment at the foot of a tower: double door, filtered ventilation, a double roof against sun load and anti-theft hinges.
A cabinet for UPS batteries with natural or forced ventilation through filtered louvres and shelves for four 100 Ah batteries.
An outdoor telecom cabinet with a 20 mm air gap between the outer skin and an inner skin, plus a laser-cut window for a heat exchanger.
300 × 1,200 × 2,000, with Coil and Fan Bays (Coil and Fans Fitted to Order)
15 products
A 2U fan-tray plate for rack cooling: three Ø80 fan cut-outs, folded 15 mm returns and ear holes. The 2 / 4 / 6-fan options change the plate width or add rows.
The vertical cable manager that sits between racks: a 100 × 100 U with slotted sides ('fingers') to hold cables. Horizontal managers are the same section cut to a 1U or 2U length.
One fixed shelf stands for the whole family of rack accessories: patch-panel trays (1U/2U), cable-management rings, blanking panels, fan trays and shelves. The front flange carries EIA-310 ears (holes 465.1 mm apart) and the shelf is stiffened by 15 mm side returns.
A 1U patch-panel tray, 250 deep: a shallow shelf that carries a patch panel and the cable bend behind it.
Specialised components for cable organisation. Made to order in CRCA 1.2 mm / plastic-coated, to your drawing.
A bracket that carries a vertical PDU on the rear of a cabinet; the keyhole slots are punched to the PDU maker's drawing.
A 1U sliding tray for a keyboard or KVM console: the shelf is like the fixed rack shelf but longer, mounted on ball-bearing slides.
More in this group: Blanking and Brush-Strip Panels · Overhead Cable Ladder for Data Halls (300 / 450 / 600 Wide) · Top-of-Rack Cable Tray Kit · Heavy-Duty Server Shelf · Rack Battery / UPS Shelf · Horizontal Cable Manager · Pole-Mounted Outdoor Cabinet Bracket Kit
15 products
A wall-fixed arm frame carrying a 60.3 mm mast for a panel antenna. Made to order in GI angle 40-50 mm, HDG, to your drawing.
The bracket that holds the feeder-cable ladder (or a pole clamp arm) on a tower or rooftop pole: 6 mm plate bent into an L with a welded gusset and two Ø14 holes for the U-bolts.
More in this group: Raised-Access-Floor Pedestal and Stringer Kit · Cooling-Unit Floor Stand (Downflow CRAH Plinth) · Data-Centre Staging / Build Bench · Server Transport Cart · Outdoor Cabinet Plinth / Base Frame · Rooftop Ballasted Mast Base for Antennas · Control-Room Video-Wall Mounting Frame
5 products
42U to 48U racks, open frames, wall-mount and outdoor cabinets
ExploreBattery racks, charger cabinets, inverter enclosures, smart-meter boxes
ExploreSend a drawing: punching, laser, forming, welding, finishing
ExploreYes. Height, width, depth, door type, finish and fittings are specified for each order. Send a drawing or describe what you need.
We make the rails, brackets, fan-tray cut-outs and cable managers, and fit parts you supply or specify. Tell us what you will install.
Yes: double-wall sun-shielded cabinets, battery cabinets and pedestals. Ingress protection is a design target confirmed by test on the first article.
Tell us what you need for telecom and data centres: the product, the size, the material and how many. We reply with a clear quotation.