Server racks and network cabinets

Server racks and network cabinets, floor-standing

Closed floor-standing cabinets for servers, switches and storage: 42U to 48U, 600 and 800 mm wide, with perforated or split doors, cable entries in the roof and floor, and provision for cooling.

42U to 48U600 and 800 mm widePerforated and split doors
Server racks and network cabinets, floor-standing

Choose from a standard 42U network cabinet, a deeper colocation cabinet with a separate lock on every door leaf, a 47U network core rack with integral cable managers, a seismic-ready rack with floor anchoring and top bracing, and a 48U rack for GPU servers with provision for liquid cooling. Every rack is made to order, so width, depth, door type, finish and fittings follow your specification.

Which rack for which job

  • Network and server cabinet, 42U: the general-purpose choice for servers, switches and storage in an equipment room.
  • Colocation cabinet: front and rear doors split into two leaves, each with its own key, so several users can share a cabinet.
  • Network core rack, 47U: high-density cabling with integral vertical cable managers; bays side by side.
  • Seismic-ready rack: floor-anchored with top bracing. A seismic zone rating is a test result, so give us your test requirement and we quote against it.
  • GPU server rack, 48U: reinforced base and posts for heavy servers, with manifold support brackets for liquid cooling.

Products in this range

Telecom & Data Centre

19" Server Racks

Standard rack enclosures for IT equipment mounting. Made to order in CRCA 2.0 posts, 1.2 panels, to your drawing.

Details
Telecom & Data Centre

Server Cabinets

A premium server cabinet 600 wide × 1,200 deep: the extra depth takes long servers and the cable space behind them.

Details
Telecom & Data Centre

Network Cabinets

A 24U network cabinet 600 × 600 for switches and patch panels: lighter 1.5 mm posts, a glass or perforated front door and a fixed rear door.

Details
Telecom & Data Centre

Data Centre Racks

A high-density rack with 2.5 mm posts, 80 % open doors and sealing strips so it works in hot/cold aisle containment.

Details
Telecom & Data Centre

Floor Standing Cabinets

A 32U enterprise floor cabinet with lockable doors and side panels and cooling-ready roof cut-outs (height between the 24U and 48U ends of the range).

Details
Telecom & Data Centre

Colocation Cabinet

42U 800 × 1,100 with Individually Keyed Split Front and Rear Doors

Details
Telecom & Data Centre

Open Rack

21-Inch, 48 OU Frame, Busbar-Ready (OCP ORv3-Style)

Details
FAQ

Questions buyers ask

What is the difference between a rack and a cabinet?

A rack is an open frame that holds 19-inch equipment. A cabinet is a rack with side panels, a roof and lockable doors. Cabinets protect equipment and control airflow; open racks give easy access and low cost.

How do I choose the depth?

Measure your deepest server, add space for power and network cables at the back, and add the door. Network gear fits 600 to 800 mm cabinets; deep servers usually need 1,000 to 1,200 mm.

Can you fit PDUs, fans and cable managers?

Yes. Tell us what you will install, and we make the rails, brackets, fan-tray cut-outs and cable managers to match, or fit parts you supply.

Do you make non-standard sizes?

Yes. Heights, widths, depths, door types and finishes are specified per order. Send a drawing, or describe what you need.